Go to content
Skip menu
PAMS Pacific Admiralty Maritime Services  Ship Inspections
PAMS Pacific Admiralty Maritime Services
Skip menu
Independent Marine Surveying & Ultrasonic Testing

Ultrasonic Hatch Cover Tightness Testing

PAMS Pacific Admiralty Maritime Services provides independent ultrasonic hatch cover tightness testing to identify and localise potential leakage paths through cargo hatch cover sealing arrangements. This non-destructive method uses high-frequency sound to assess sealing integrity without requiring water application over the hatch covers.

Independent Ultrasonic Hatch Cover Tightness Testing

Hatch covers are a critical barrier protecting vessel cargo spaces against seawater ingress. Defective rubber packing, compression loss, damaged sealing surfaces, misalignment and deterioration of securing arrangements can compromise their weathertight integrity.

Ultrasonic hatch cover tightness testing is a non-destructive inspection method used to identify potential leakage paths through closed hatch cover sealing arrangements. A transmitter placed inside the cargo hold generates a high-frequency ultrasonic signal. A surveyor on deck uses a calibrated ultrasonic receiver to scan the hatch cover perimeter, cross-joints and other relevant sealing interfaces.

The method can be applied to suitable vessel arrangements with empty or loaded cargo holds, subject to the test procedure, access conditions, equipment configuration and applicable safety requirements.

Inspection objective: To identify, locate and document potential ultrasonic leakage paths through hatch cover sealing arrangements, supporting technical assessment and corrective maintenance before or during the vessel's operational programme.

Principle of Ultrasonic Hatch Cover Testing

Ultrasonic tightness testing is based on the transmission and detection of high-frequency sound. When a cargo hold is suitably enclosed and the transmitter is activated, ultrasonic energy can pass through openings in the hatch cover sealing arrangements.

The receiver detects the ultrasonic signal from the deck side. Changes in the measured signal provide an indication of potential leakage paths and help the surveyor identify locations requiring closer examination.

Ultrasonic Transmitter

A transmitter is positioned inside the cargo hold and emits a high-frequency ultrasonic signal. The equipment arrangement and signal output are established in accordance with the applicable testing procedure.

Ultrasonic Receiver

A handheld receiver with a directional sensor is operated from the deck side to detect and measure ultrasonic energy passing through hatch cover sealing interfaces.

Reference Measurement

A reference reading is established using the equipment manufacturer's prescribed procedure. This provides a basis for comparison with measurements taken during the closed-hatch test.

Leakage Path Identification

Variations in detected ultrasonic readings are evaluated to identify potential openings or discontinuities in the sealing arrangements requiring investigation.

Ultrasonic Hatch Cover Testing Procedure

The test is carried out through a systematic sequence of preparation, transmitter positioning, reference measurement, deck scanning and recording of results. The precise procedure must follow the equipment manufacturer's instructions and the applicable inspection requirements.

1. Test Preparation

The hatch cover arrangement, cargo hold access, vessel condition and inspection requirements are reviewed. The hold and hatch cover are prepared for testing, with attention to safe access and the agreed test scope.

2. Transmitter Placement

The ultrasonic transmitter is positioned inside the cargo hold in accordance with the equipment procedure. Its location and operating condition are established before deck-side measurements commence.

3. Reference Reading

A reference measurement, where required by the equipment procedure, is taken to establish the comparison value. The Open Hatch Value (OHV) may be used as a reference parameter in equipment systems that apply this method.

4. Hatch Closure

The hatch cover is closed and secured in its normal operating configuration. The surveyor confirms the test arrangement and relevant conditions before scanning.

5. Deck-Side Scanning

The receiver is moved along the hatch cover perimeter, cross-joints, panel joints and other relevant sealing interfaces to detect variations in ultrasonic signal readings.

6. Findings and Recording

Relevant readings, identified leakage locations, test conditions and observations are recorded. Findings are evaluated in accordance with the applicable procedure and acceptance criteria.

Ultrasonic hatch cover tightness testing on a bulk carrier using deck-side receiver equipment

Ultrasonic Hatch Cover Tightness Test

Deck-side ultrasonic scanning is performed along hatch cover sealing interfaces to identify and record potential leakage paths.

Open Hatch Value (OHV) & Reference Measurements

The Open Hatch Value (OHV) is a reference measurement used in certain ultrasonic hatch cover testing systems. It establishes a baseline signal reading under the equipment manufacturer's prescribed open-hatch reference conditions.

Following the reference measurement, the hatch cover is closed and secured. The receiver is then used to scan the relevant sealing interfaces. The measured signal can be compared with the reference value, depending on the equipment's measurement system.

Reference Measurement Considerations

  • Equipment manufacturer's instructions and calibration requirements.
  • Correct transmitter positioning and operating configuration.
  • Reference measurement conditions and recording of baseline readings.
  • Consistent receiver positioning and scanning technique.
  • Interpretation of measured values using the applicable equipment criteria.
  • Recording of environmental and operational conditions that may affect measurements.
Technical interpretation: OHV is a reference parameter, not a universal acceptance limit. Reading interpretation and pass/fail assessment must follow the specific equipment procedure and the applicable testing criteria.

Hatch Cover Areas Subject to Ultrasonic Scanning

The scanning programme should cover the relevant hatch cover sealing interfaces and other potential leakage locations. The extent of testing depends on the hatch cover design, arrangement, access and agreed inspection scope.

Perimeter Rubber Packing

Scanning along the perimeter sealing arrangement to identify potential signal transmission through defective, deteriorated or inadequately compressed gasket areas.

Cross-Joints

Examination of sealing interfaces between adjacent hatch cover panels, where discontinuities, wear or inadequate compression may create potential leakage paths.

Panel Joints

Scanning of relevant panel connections and longitudinal sealing interfaces to identify areas where the ultrasonic signal may pass through an opening.

Compression Areas

Examination of sealing locations where compression loss, uneven contact or deformation may affect the effectiveness of the hatch cover sealing arrangement.

Coamings and Corners

Attention to corner arrangements, coaming interfaces and changes in sealing geometry that may require additional scanning.

Additional Leakage Locations

Other relevant hatch cover interfaces and potential leakage paths are examined where required by the hatch cover configuration and testing scope.

Ultrasonic Leakage Detection & Signal Interpretation

During scanning, the receiver detects ultrasonic energy transmitted through openings in the hatch cover sealing system. Changes in the displayed reading can indicate a potential leakage path and assist the surveyor in identifying its location.

Typical Findings Requiring Attention

  • Potential leakage paths along perimeter rubber packing.
  • Signal transmission through cross-joint sealing interfaces.
  • Possible gaps associated with inadequate gasket compression.
  • Localised readings indicating potential discontinuities in sealing contact.
  • Variations between adjacent sections of a sealing arrangement.
  • Areas requiring closer examination or maintenance attention.
Reading assessment: A detected ultrasonic signal is an indication requiring evaluation under the applicable test procedure. The receiver reading alone does not establish the exact physical dimensions of a gap or independently quantify the amount of water that could enter the cargo hold.
Marine surveyor using an ultrasonic receiver to scan hatch cover rubber packing and cross-joints

Deck-Side Ultrasonic Receiver Scanning

The receiver is used to scan hatch cover sealing arrangements and identify locations where further examination or corrective maintenance may be required.

Ultrasonic Testing Equipment & Technical Controls

Reliable ultrasonic testing depends on suitable equipment, correct operating procedures and competent personnel. The transmitter and receiver must be used in accordance with the equipment manufacturer's instructions and applicable testing requirements.

Ultrasonic Transmitter

Generates the high-frequency signal inside the cargo hold. Equipment output, positioning and operating conditions should be verified before testing.

Ultrasonic Receiver

Detects and displays the ultrasonic signal from the deck side. Directional sensing and suitable scanning technique assist with identifying potential leakage locations.

Calibration and Verification

Equipment condition, calibration status and functional checks should be established in accordance with manufacturer instructions and applicable requirements.

Test Documentation

Equipment identification, reference readings, test conditions, measured values and relevant findings should be documented as required by the inspection procedure.

Advantages of Ultrasonic Testing Compared with Hose Testing

Ultrasonic testing offers practical advantages in circumstances where water application is undesirable or operationally difficult. It can complement conventional methods and provide a means of locating potential leakage paths without spraying water over the hatch cover.

No Water Application

The method does not require water to be sprayed over the hatch cover sealing arrangements, avoiding the water runoff associated with conventional hose testing.

Suitable for Loaded Holds

Testing may be possible with cargo in the holds, subject to suitable transmitter access, vessel arrangements and safe operating conditions.

Localised Signal Detection

Signal variations help identify locations requiring closer examination, rather than relying solely on observation of water penetration inside the cargo hold.

Operational Flexibility

The method avoids water application and may reduce disruption associated with hose testing, subject to access, preparation and port operating conditions.

Cold-Weather Application

Since the method does not depend on water application, it avoids the freezing and runoff concerns that can affect hose testing in low temperatures.

Non-Destructive Assessment

Ultrasonic testing assesses potential leakage paths without requiring physical alteration or dismantling of the hatch cover sealing system.

Actual testing duration, operational impact and suitability depend on the vessel configuration, cargo condition, access arrangements and agreed testing procedure.

Ultrasonic Testing and Conventional Tightness Tests

Different hatch cover tightness verification methods have different practical applications. Selection should take account of the test objective, vessel condition, cargo status, access and applicable acceptance requirements.

Ultrasonic Testing

Detects ultrasonic signal transmission through potential openings in sealing arrangements. It does not require water application and can help localise suspect areas.

Hose Testing

Applies a controlled water stream to hatch cover sealing areas. Leakage is assessed through observation of water penetration or ingress on the inside of the cargo hold.

Chalk or Contact Tests

May be used to examine contact and compression characteristics of sealing arrangements. These methods do not provide the same ultrasonic signal detection capability.

Method Selection

The selected method should be appropriate to the hatch cover arrangement, intended verification, cargo condition and applicable inspection criteria.

Complementary inspection: Ultrasonic testing does not replace visual examination of hatch cover components or necessary maintenance inspections. Where required, different testing methods may be used together to provide a more complete assessment.

Testing Limitations & Conditions

Ultrasonic tightness testing is a technical inspection method whose reliability depends on the test arrangement, equipment condition, operating procedure and interpretation of the results. The method should not be treated as an unconditional guarantee of hatch cover watertightness under every operating condition.

Important Technical Considerations

  • Suitable transmitter positioning and access inside the cargo hold.
  • Correct closure and securing of the hatch cover before scanning.
  • Equipment calibration, functional condition and manufacturer requirements.
  • Consistent scanning technique and appropriate receiver positioning.
  • Hatch cover design, panel arrangement and sealing configuration.
  • Access restrictions caused by cargo, vessel operations or safety conditions.
  • Interpretation of readings against the applicable equipment procedure and acceptance criteria.
  • Identification of areas that cannot be examined or tested during the attendance.
Scope limitation: The results represent the conditions and equipment configuration at the time of testing. They should be considered together with visual examination, maintenance condition and any additional verification required by the relevant parties.

IACS Unified Requirement Z17 – Testing Firm Requirements

IACS Unified Requirement Z17 addresses the approval and qualification framework for firms undertaking specified services on behalf of Classification Societies. Its requirements include provisions relevant to firms engaged in ultrasonic tightness testing of closing appliances, including applicable hatch cover arrangements.

The relevant requirements concern matters such as personnel competence, equipment, documented procedures and the firm's technical capability to perform the specified service.

Relevant Technical Considerations

  • Personnel competence and qualification for the assigned testing activity.
  • Appropriate ultrasonic testing equipment and its condition.
  • Documented testing procedures and operating instructions.
  • Equipment calibration and verification arrangements.
  • Recording and reporting of testing results.
  • Compliance with the applicable Classification Society approval requirements where the service is performed on its behalf.
Regulatory distinction: IACS UR Z17 should not be interpreted as automatic approval of every testing company or as a universal acceptance certificate for each hatch cover test. Approval and recognition requirements depend on the applicable service, Classification Society and assignment.

Applicable requirements and their current revisions should be checked against the relevant IACS and Classification Society documentation before undertaking work requiring formal approval.

PAMS Ultrasonic Hatch Cover Testing Process

PAMS undertakes independent technical inspection assignments using a structured approach based on the vessel's hatch cover arrangements, test objective and agreed scope of work.

Assignment Review

Review of vessel particulars, hatch cover arrangement, intended testing scope and applicable technical requirements.

Equipment and Test Preparation

Review of equipment suitability, access arrangements, test conditions and required safety precautions.

Ultrasonic Testing

Transmitter positioning, reference measurements where applicable, hatch closure and systematic deck-side scanning.

Technical Evaluation

Assessment of measured readings, identified signal variations, test limitations and relevant observations.

Findings and Recommendations

Identification of suspect sealing locations and recommendations for further examination, adjustment, repair or maintenance as appropriate.

Inspection Reporting

Preparation of a technical record of the testing scope, equipment details, results, observations and limitations.

Ultrasonic Hatch Cover Testing Report

A technical report provides a documented record of the ultrasonic testing attendance and its findings. The report content is determined by the agreed scope, equipment procedure and applicable requirements.

Typical Report Contents

  • Vessel identification and relevant particulars.
  • Inspection location, date and attendance details.
  • Hatch cover identification and arrangement tested.
  • Scope of testing and applicable procedure.
  • Ultrasonic equipment identification.
  • Reference readings and OHV details where applicable.
  • Recorded readings and identified suspect locations.
  • Observations concerning sealing arrangements.
  • Photographic records where available and relevant.
  • Test limitations and inaccessible areas.
  • Technical findings and recommendations.
Reporting objective: To provide an objective technical record of the ultrasonic test and identify areas where further examination or corrective action may be required.

Independent Marine Surveying & Technical Consultancy

PAMS Pacific Admiralty Maritime Services is an independent Philippine marine technical consultancy providing marine surveying, inspection and engineering services.

Ultrasonic hatch cover tightness testing is treated as a technical inspection assignment, with findings documented according to the agreed scope, testing procedure and requirements applicable to the vessel.

Our approach focuses on objective observations, appropriate testing methodology, technical interpretation and clear reporting of identified conditions and limitations.

Independent professional position: PAMS Pacific Admiralty Maritime Services provides independent marine technical consultancy and surveying services. It does not provide ship agency, husbandry, crewing, recruitment, bunker-call, freight or logistics services.

Ultrasonic Hatch Cover Tightness Testing – Frequently Asked Questions

What is ultrasonic hatch cover tightness testing?

Ultrasonic hatch cover tightness testing is a non-destructive method used to identify potential leakage paths through closed hatch cover sealing arrangements. An ultrasonic transmitter is placed inside the cargo hold while a receiver is used on deck to detect signal transmission through potential openings.

How does ultrasonic hatch cover testing work?

A transmitter generates a high-frequency ultrasonic signal inside the cargo hold. After the hatch cover is closed and secured, a surveyor scans the relevant sealing interfaces from the deck side using an ultrasonic receiver. Variations in detected readings help identify potential leakage locations.

What is the Open Hatch Value (OHV)?

The Open Hatch Value is a reference measurement used in certain ultrasonic testing systems. It establishes a baseline reading under the equipment manufacturer's prescribed reference conditions for comparison with subsequent closed-hatch measurements.

Can ultrasonic testing be carried out when cargo holds are loaded?

Testing may be possible when cargo holds are partially or fully loaded, provided the transmitter can be suitably positioned and the test can be performed safely. Suitability depends on vessel arrangements, cargo condition and the equipment procedure.

Does ultrasonic testing require water?

No. Ultrasonic testing does not require water application over the hatch cover sealing arrangements. This is one of its practical advantages compared with conventional hose testing.

Which hatch cover areas are examined?

The scanning scope may include perimeter rubber packing, cross-joints, panel joints, compression areas, coaming interfaces and other relevant sealing locations, depending on the hatch cover design and agreed test procedure.

Can ultrasonic testing identify the exact location of a leak?

Ultrasonic scanning can help localise areas where signal transmission indicates a potential opening in the sealing arrangement. The accuracy of localisation depends on equipment capability, scanning technique, access and test conditions.

Is ultrasonic testing better than hose testing?

Each method has different applications. Ultrasonic testing does not require water and can help localise potential leakage paths. Hose testing applies water to the sealing arrangements and checks for water penetration. The appropriate method depends on the vessel, cargo condition and inspection objective.

Does ultrasonic testing replace visual hatch cover inspection?

No. Ultrasonic testing should be considered together with visual examination of rubber packing, compression bars, cleats, coamings, drainage arrangements and other relevant hatch cover components.

What is the relevance of IACS UR Z17?

IACS Unified Requirement Z17 addresses approval and qualification requirements for firms undertaking specified services on behalf of Classification Societies, including relevant provisions for ultrasonic tightness testing of closing appliances. Applicable approval requirements depend on the service and Classification Society involved.

What does the ultrasonic test report contain?

A technical report may include vessel and hatch cover identification, testing scope, equipment details, reference readings where applicable, recorded measurements, identified suspect locations, observations, limitations and recommendations.

Does a successful ultrasonic test guarantee that hatch covers will never leak?

No. The result represents the conditions and test configuration at the time of examination. It does not guarantee future performance under every weather, loading or operating condition. Hatch cover maintenance and continued condition remain important.

Can PAMS undertake independent ultrasonic hatch cover testing?

PAMS Pacific Admiralty Maritime Services provides independent marine surveying and technical inspection services. Specific ultrasonic testing assignments are subject to equipment availability, personnel competence, applicable approval requirements and the agreed scope of work.

Technical Scope & Inspection Review

This service page describes the technical principles and application of ultrasonic hatch cover tightness testing, including transmitter positioning, reference measurements, deck-side scanning, signal interpretation and reporting.

The testing procedure and acceptance criteria should be established with reference to the equipment manufacturer's instructions, hatch cover arrangement, applicable requirements and the specific assignment.

Test findings are based on the agreed scope, equipment configuration, accessible areas and conditions observed at the time of attendance.

Require Independent Ultrasonic Hatch Cover Testing?

Contact PAMS Pacific Admiralty Maritime Services to discuss ultrasonic hatch cover tightness testing, hatch cover sealing assessments and independent marine inspection requirements.

Contact PAMS Marine Survey Services Cargo Hold Inspection
Back to content